I replaced the rod, and now my lid will not go down, the rod is the exact same as the other. Hi Carolyn, When a pump displays those symptoms, its usually an air leak or a collapsed suction hose, or a very dirty filter. Hope you can help! "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Is there a disconnected wire in the back of the motor? "width": "611",
Pushing down on the handle briefly (pump off) can often dislodge the debris, and no gasket replacement is necessary if you are lucky. The filter pressure on low should only be a few psi. Our Hayward pump is leaking and we just added our opening chemicals. "logo": {
Even though the motor is only 2 months old and had very little run time, bench running it sounds pretty horrible. If the pump is on high when it is supposed to come on the pump motor humms and cuts off. Wait for the number to. There is also a leak somewhere in the system because there is water on the pad. check that everything is tight and aligned. Features: Replacement for Hayward T-CELL-5, GLX-CELL-5-W and Aqua Trol Suitable for pools up to 20,000 gallons Comes with a 15 foot cord Clear housing for visual inspection of cell No need for re-plumbing, direct fitting threads Meets all original factory specifications Reverses polarity to automatically clean cell Only half of my cell gets clogged up and the other half stays clean. Gauge was reading between 6 and 8 on filter container at this time. Another possibility could be a clogged pump impeller, should have mentioned that earlier. Hi David, spilling water on the motor is no problem, they do fine outside in the rain (flooding is a different story) Have you checked the GFCI test button on the outlet? The most common areas for an air leak are the pump lid (is it as tight as possible? Is the motor still good. It was probably spouting water several feet in the air, which soaked the motor, and popped a breaker? Check the incoming voltage to be sure that you are within the range of 110V-125V. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools. Lets see what we can do Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. If not, the parts internally, some parts, need replacement. Is the water level ok in the pool, and the skimmer weir is not stuck? Is this normal operation or should I look into replacing the strainer cover o ring? After 15-20 minutes, after cooling, the switch will close again, and the motor should restart. Is there a break in period for the unit or do I need to call the technician? Good morning. That motor is sometimes used on the Hayward Superpump which is the only pump with a SQUARE pump basket. Now it runs nice and quiet but still overheats and shuts off. If I block the outflow from it, it stops clicking on and off, and runs smoothly. I have a pre-2008 Northstar pump and it seems to be losing air seal. As soon as I hook it up and it starts pumping water the pump slows down and struggles, the sound is very noticeable. I have it set for a T9 cell. The blower will run until error condition is corrected. Ill look up the Drain King, is that something like a check valve? Inherited an old Hayward super pump that hums but doesnt turn over, checked the shaft which moves smoothly and replaced the starter capacitor to no avail. Reset is immediate after error is corrected. Basically it ran normal and then would get loud, and then go back to normal. low speed works fine, pump is three years old. Any new postings here are unlikely to be seen or responded to by other members. Also you can test the outlet with another small plugin item, like a hair dryer or lamp. hayward salt cell plumbing diagram blue essence 20 manual hayward aquarite troubleshooting guidehayward salt system troubleshooting aqua rite diagnostic codes Blue essence salt chlorine generator owner's manual Salt Chlorinator Cell Replacement, Salt Water System Parts, Pool Light, Pool Alarm, Pool. if it does not come back on, check switches, turn breaker all the way off and back on again. I even removed the outflow from the filter and ran that directly in case the filter was clogged. Hi the strainer housing must need to be tightened up. If the filter pressure goes higher when this happens, it could be an obstruction inside the filter or filter valve, or after the filter on the return line. Hi Yolanda, also a great question first plug something else like a hair dryer or lamp into the outlet, to be sure its supplying 115V properly (or use a test meter). Test the capacitor for voltage, or just replace with exact MFD no. We have cleaned it 3-5 times a day and changed the d.e as well. Replumb your flow switch if it does not meet the distance requirements. Check all connections, circuit breakers, and fuses. Does anyone know what Im talking about and/or know how to repair? All the leds remain off and the display shows the salt concentration 2900. I even tried another new housing gasket and it still leaks. dhp faux leather club chair; hanna salinity tester calibration; Hayward pro lx 1.5hp pump turns on for 5 seconds, shuts off, then light to moderate, white electrical smoke from pump. Also, using Teflon pool lube on the pump lid oring should help. have an old hayward flo lx pump and sounds like it is turning on with a click but wont start sucking the water from the pool through the pump to the filter. Do you have any suggestions? Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. Hi Dave, we are replacing a Hayward superpump 1.5 horsepower with the same pump. New Assy is $500. Find these plugs and remove them by loosening the wingnut and wiggling it out. I took the lid of the pump basket and cleaned the seal and placed it back on tightly, but there are small bubbles still coming out of the pool jets. Hi Don, when its not an air leak, pump surging will then be an obstruction in the pipe, or filter, heater, check valve/filter valve/diverter valve, a bit of plastic usually (once I found a golf ball, in the skimmer pipe), that is pulled into a 90 or up against a port that is too small for the obstruction to pass. Another piece of information is that the board was replaced back around May of this year as well as the flow sensor. To keep the water clear, hand feed liquid or granular chlorine daily, and brush/skim the pool daily. Could be the use of a clarifier or flocculent that is clogging the sand? We have a Hayward ultra pro lx series pump for our above ground pool. Everything just went downhill. Hello my Hayward pump before it starts it buzzes for a few seconds and stops for a few seconds then repeats and after a couple of trays it starts running normal. Is this normal? "@type": "Organization",
I backwash and rinse and start again but it does the same thing. . Perhaps you can replace it with a 20 amp breaker, of the same manufacturer, and youd be all set, or move some of the other devices to draw power from a different breaker. Then, take a look at the capacitor, located at 9 oclock. Have zero skills with pool pump filter motors or basically anything associated. If needed, get yourself ECX1014A, bump shaft kit, for a little rebuild. Lube should not be the issue with the leak, not required. The wire size may depend on the distance of wire run. Thank you. If stuck from rust build-up, move the capacitor (located at 9 oclock) and/or the thermal regulator (located at 12 oclock), out of the way, so that you can fit a 7/16 open end wrench on the slotted part of the shaft, behind the centrifugal switch that is screwed onto the end of the shaft. I have an sp3400vsp pump. 7. inspect breaker, turn off breaker to pool from house main panel). Also that some circuit breakers used can create such noise as to cause problems with this error message. Water temperature is above 140 degrees F. Make sure that either 120VAC or 240VAC input power is connected to the proper screw terminals at the Aqua Rite control. Hi Andy, good question thanks Motor will start on low, but not on high. The idea is to cut the pipe above the pump, and crank the fitting 1/2 turn tighter, to open the crack, pump it full of superglue and then quickly unthread the pipe out of the pump, at which point the crack will close up, and hopefully seal up. Hi Julie, is the FLO error code on the heater? Blocked air vents and no air flow is also a possibility. If they are tight, pull out the cartridge and drain the tank whatever it is may be laying in the bottom of the tank. I have a Hayward super pump every once in awhile when I go to unplug to backwash it sparks and trips the breaker. I have a problem when the heater warms up it blows bubbles/cloudy bubbles. Thanks. I ended up buying a new Hayward pump online however dont want this to happen again. Now the backwash is leaking a small amount water and the pump seems to be surging instead of running smoothly. Could be a short in the wiring that could be tested with an Ohm meter, for resistance. I need some advice for my 15 x 30 x 48 AG oblong swimming pool. But, that may not be it, if you say the shaft is getting stuck each time? My Hayward pump II LX 1.5 horsepower. Motor again started humming and had to repeat the above steps each time I moved to backwash. If the pump makes no noise at all, turn on power, and with a multi meter, check the power at the pump, switch/timer and breaker, the problem lies where the power dies. Automatic reset is immediate after error is corrected. This is a brand new pump out of the box that was installed and the inlet is drawing water in and filling basket and the outlet is discharging water but it just trips the breaker everytime. However, when I check the connection at the wired, there is definetly juice there. I have a Hayward power-flow matrix pump with hayward preflex extended cycle D.E. The 1.5 hp pump was so strong you couldnt stand in front of the single return, which is why I used smaller pump. Hi, each pool filter system has a different pressure, but if there was a normal pressure, many systems are designed to run around 10 psi (clean). UNK the , . Grids not aligned properly, thus not pushed fully up into manifold Motor may still be good. The print and bearings were replaced. "width": "611",
You can remove the pump basket and reach back with your fingers to see if any debris can be felt in the eye of the impeller (pump Off, of course, lol). Check that hoses are clamped tight to fitting. I checked valves inside pump, and new o ring was installed. Air could also be entering the pump from the threaded pipe or union that is attached to the inlet port, which may also spray or drip when the pump shuts off. Hi Kenny, not to my knowledge, you should see some display even without gas hookup. Its that time of season to close the pool, I am probably going to close the pool and worry about the tripping breaker next year. If the gears are not moving, either the motor for the clock is dead, or insects or lizard is stuck in the gears, or the breaker is tripped or off, or the breaker is bad. Do you know what the problem is? gives you instant access to PDF files. What more can I do or will the bubbles resolve on its own? Could also be that your vacuum hose has a big split in it if this only happens during vacuuming. Glad that you replaced the sand, normally lasts 5-7 years on larger sand filters, but filters below 21 diameter need it more often, and very small filters 12-14, need it almost every season. Thanks. There may also be air leaks on your pump, particularly the pipe or valve that is threaded into the pump, must be sealed with thread sealant tightly. Hi Jodi, that could be two things either the pump impeller is severely clogged, keeping the motor shaft from turning or if the shaft spins freely, it is likely the capacitor (black cylinder in rear of motor) that has failed. Hi Michelle, If the pump and motor are too large and powerful for your filter size, it would create this situation. Might be 2-years here is a chart on reading Hayward serial numbers, to find date of manufacture https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, I have to reprime my hayward pump everytime I turn it on.
I Manually turned the shaft (which was not turning freely), while the motor was humming. Tried to backwash. When it stops again, you may want to pull off the filter valve from the filter, and inspect the top few inches of sand, maybe replacing it with new. This year, I have replaced all the plumbing from the pump to the filer. But your superpump is fine on your AG pool. Have a Hayward variable that was replaced last year. If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. Turned it off and now it makes the grinding noise and turns off itself. Hi Ray, NOW you may have a bad capacitor. Could also be a loose high speed wire from the switch. I turned the gas off to it. I did find the black power wire lose on the pump when checking the wire connections, so I reconnected it but to no avail. If you have an automatic controller, it could be a rickety relay or something. "width": "611",
"caption": "In The Swim Blog"
I doubt you damaged anything, or have any big issues, should be OK. Check the impeller and seal alignment. Any idea why I would be drawing more current? I have great circulation, but I the problem is after the pump runs for around a half hour on the filter setting it barely has any force coming out of the jet. Please help! Step 3: Double check the wires on the flow switch for damage. The water level is good. When you installed the new lateral assy, did the standpipe come all the way up to the top of the tank, and insert neatly into the bottom of the multiport valve? what do you think the hum could be? For the clamp band, yes the washer with the slightly smaller hole I.D. If you have a multiport valve, set it on Recirculate, to bypass the filter, and rule out any problems there. Did you figure this out. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical Full membership to the IDM is for researchers who are fully committed to conducting their research in the IDM, preferably accommodated in the IDM complex, for 5 We would like to show you a description here but the site wont allow us. Went out today to find the lower plastic shroud melting again? Excessive voltage or amps can cause the problem. Interesting enough, if I place it in super chlorinate mode, it will produce chorine. Should it be very hot to touch or is this an indicator for a capacitor problem? Thoughts? I turned it off overnight but still the same thing. If all is good, there is a possibility that the breaker or GFCI outlet is bad. I have my pump to run each evening from 10:30pm to 9:30am. Or very high mineral content (very hard water), or oily substances. There could also be a short in the wiring to the pump, or from the breaker to the switch. Stackable Rose Gold Wedding Bands, and loosing its prime . Thanks for the comment, impellers dont normally wear out, they either work or they are flat busted and dont work. },
You can pull out the plunger and inspect, and see how it fits the valve body, at the top, should contact all sides, and be lubed well, twice per year. If all is well then 99% sure it would be the capacitor, weak and needs replacement. I dont really know if my pump can be repaired or if the only solution is buying a new pump so soon. runs normal on 110 but does not make any sound when set on 230 and wired accordingly. Second be sure that you are delivering 230V (+/- 10%) and that the motor is set to accept 230V (some are reversible to accept 115V too). When we turn on power, the pump does not make noise but the timer box and the circuit box make a light humming noise and then the circuit tripped. A corroded part will be rusted and will start to disintegrate over time. More commonly, you may experience sparks, or a small popping sound as you drain the capacitor, if there is a lot of power stored. Likewise, check if the motor is wired correctly for the available field supply voltage. I checked the 20A fuse and it is good. Could have been an outlet problem too, make sure wires or terminals arent touching anything except each other. Signs of wear under the wear ring is normal, and it should be pumping normally. Now there is no water running from the pool to the motor basket. "@type": "Person",
Hayward Pool Products. Air leaks are another source of priming issues. If your pump is made of plastic, it must be the bearings, failing so hard that it is causing the motor to overheat. Went on to fill with water again & put on normal cycle and still was not getting a full prime. It's a little over 3 years old and the cell checked out fine. Thanks for your time. Thanks. thanks. Hope that helps! otherwise all else seems to read ok. Id check the cell number just to confirm it is the TCELL15. it will not pull up off the pump basket. have the pump motor rebuilt by replacing the bearings and shaft seal, or having an electric motor repair shop do it for you, or 2) replace the motor with an exact replacement motor + new shaft seal, or 3). Now it wont flip back on but it is still raining hard. Good luck! Step 2: Press Diagnostics button 5 times to display the Instant Salt level. new pump started up fine after primed strated to click on and off. I would guess this is what is happening, and if so your service company is either uneducated or dishonest. I was wondering if the Hayward Cyclac Ball Value could be leaking? Recently I started getting a loud vibration hum from my hayward pump. This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. Went to start the pump to prep the pool for the kids and sill attempt to turn on but then stops. Second thought is are the pipes plumbed into the valve correct? Any idea what the next most likely culprit could be? Probably not a pump or motor problem (but could be). Amp draw is 15 amps. Hi John, sounds like a thermostat issue (or potentiometer for electronic heaters), although it could be another issue that just by coincidence happens when water is warm, like low flow rates. While it is normal for an appliance plug to become warm, it is abnormal for such a plug to get hot. If the shaft is free turning, but the pump does not turn on, check power connections. Armstrong Human Resource Management 13th Edition Pdf, The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing Following this procedure will identify News Reporter Reveals On Live TV That Shes Been Secretly Recording We would like to show you a description here but the site wont allow us. Hi Sal, for the pump lid, it may help to close the incoming and outgoing valves, and open the filter air bleeder, to release the suction. Hi Davy, Im trying to remove the impeller from a Hayward 1 HP superpump. If regular loudness, its likely an air leak. Perhaps it could be flow related, if the pump is cavitating or starved for water like if you only have 3/4 or 1 pipes (?). Replace with identical MFD number, printed on capacitor. Hi, Heyward (cool name! The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing We would like to show you a description here but the site wont allow us. That is the black cylinder located in the rear of the motor, at 9 oclock. Air can also enter through split vac hoses, but since yours is new Third problem could be if the new pump moves much more water than the old pump (not all horsepower pumps are the same 2 different pumps of the same hp, can produce vastly different flow rates. Hi Craig, could be a clogged filter, needing a flush out and perhaps a filter soak in DE Filter Cleaner. Other timers will have a different switch, but all should have someway to override. I have a Hayward super pump 1.5 hp. Thank you. You may have a partially clogged burner orifice, which is the brass spray tip on the end of the burner tube, where the gas shoots out of the manifold. When I touch any other speed button, nothing happens. Especially a drip from the clamp band or the threaded fitting on the outlet port of the pump, or a dripping shaft seal, or leaking housing. Is the motor set to accept 220V, and matching what you measure at the motor terminals? Keeping the pump lid o-ring clean and well lubricated also helps, be sure to use a Teflon pool lube, and not any petroleum based (Vaseline), which makes the rubber soft and can cause cover sticking problems too. Hi when you say it shuts down, I assume you mean that the water stops flowing? I have an older Hayward Pool pump for an above ground pool. Check that the motor wiring matches input voltage, if the motor can be wired 110/220V. If your previous pump was also 230V, as it likely was Im not sure what could be the problem, probably not a bad pump, but maybe some wire is disconnected, from the terminal board to the capacitor, for example, or otherwise mis-wired, internally perhaps? Hope thats not the case. Use jumper wire to jump TH terminals. To break the rust, you spin the shaft, or impeller. Hi, if the spark/flame was where the plug meets the cord, it could be a plug problem or an outlet problem. Its a ecoclear 1.5hp. Hi, my name is Javier Salt chlorine generators are great products. If it does, check power inside of the back of the motor, with a test meter. Not sure power goes to the pump. . any ideas? Call Hayward and speak to their tech support people, for more precise advice. Please consider. No luck. There are two washers that I have on each side of the spring. Entire pump system with pump basket and housing. },
Thank you Pressing on/off buttom followed only by click sound of switch. How do I get the lid tight enough? Hi Jennifer, many Matrix pumps have an on/off switch on the rear bottom of the motor cap end. After troubleshooting using your TS guide, I found on page 36 where it says to check the top rectifier I have 24VAC from the board (where the orange wire plugs into) to the ground. I just purchased a new pump and installed it but once all the hoses are connected even with the pump off the pump is leaking from the strainer housing. Do I need to use lube on the gasket, how much sand should be in the filter? All components of the Aqua Rite System are showing good readings and appears to be all set correctly. the loosed its prime again. On an Intermatic timer clock, there is a tab, at around 4 oclock on the dial, that is pushed to the left to turn off the timer, or override the timer settings. Please remove additional products. It was working fine (all 3 speeds) until yesterday. I dont see any leaks n pressure seems little bit higher than normal. (returns are the lines going back to the pool, returning) Some pools can operate successfully with fewer than the original pipes, I have worked on many pools with abandoned main drains or skimmers that stopped working. To spin the shaft, to find out of it spins freely, open up the rear of the pump motor, with power off, and use your fingers to spin the shaft. Hi there, I made the very unfortunate decision to rent my home to a friend. Hope that helps! I have a hayward pump installed as a new this March, 1.5 hp motor with a 23 inch filter to support a 12,000 gallons pool, it was working properly the first 3 months occasionally motor shut off and it wasnt by the breaker, since a week motor keep running only by 20 ,ins and suit off, touching the motor it is hot, I review filter pressure it is 15 psi, it is the same since installation. On traditional intermatic time clocks, you also have to make sure the timer dogs are tight, or they can slip, use pliers to tighten the nut tighter to avoid. Hi Doug, could be a bad breaker, or bad wiring between the pump and breaker. The motor can be tested briefly without being bolted onto the pump. I would say you are likely needing a new motor, and pump. Incorrect sizing can cause multiple problems, including low water flow. The 2 bolts connecting it to the platform just turn and turn and go nowhere. Hi Christy, there may be a GFCI test button that popped, on an outlet below the breaker box, or on a light pole? First inspect wiring, to be sure everything is tight and secure, and there are no loose wires, or anything that looks wrong back there. it runs about 30 minutes and trips the breaker. Meaning that your control (circuit board) may be damaged, or perhaps the cable is damaged or not connected fully. One thing I discovered is that if I place it in super chlorinate mode today, once the pool pump shuts down for the day, the next day when it turns back on, it will be back in regular chlorinate mode even if the switch is still in super chlorinate mode. switch in the center. I have a Hayward 1.65 variable speed pump it is on a timer for high and low. Hi Javi the capacitor on the motor may have failed. Home / Pool Equipment / Pool Pumps / Hayward Pool Pump Troubleshooting. Another reason for a smoking pump is an incorrectly installed shaft seal, or blown capacitor. You can also check that the phone cord wire is plugged into the interface, on underside. Any thoughts? APPLY FILTER Pumps Filters Heaters Cleaners Sanitization Automation Lighting White Goods Accessories Solar Safety Put your power leads on both sides of the transformer, should be 115V IN, and 28V OUT, (or close to those numbers). If the breaker is GFI, those are very sensitive, could be a bad breaker too. Usually get 3-4x that long. Loose wire connections or touching terminal connections cause sparking. The Filter Design Flow Rate is usually printed on the label, or can be found online. Flipped the timer on, water shot up about 10 feet and went all over me and the timer and the breaker blew. My Hayward xstream filter pump is not turning on at all. You could also check incoming voltage, and wire connections, as fluctuating current can cause an overheated motor, but if its very old, it may just be on its way out, sorry to say at which point you could replace just the motor and shaft seal, or the entire pump. Hi, it does sound like a bad seal yes. Step 2: Select your product type. We have a few of them, but maybe not the correct one for your motor, replace with the exact same MFD number, printed on the cap. After we run the pump for a few minutes and then take the pump apart there is water in the impeller- but the water is where the seat housing is.